ELECTRIC FURNACES
Electric Furnace Repair
Quincy, MA
The thermostat says 59 and the vents blow cold. With no flame to blame, an electric furnace fails in a short list of parts: heating elements, sequencer, limit switch, blower motor, breaker. We test each one with a meter, show you the dead part, and find what burned it out, so it does not fail twice. You get the price in writing before work starts, and a 60 to 120 minute arrival window on no heat calls.
$89
Diagnostic
$175 to $400
Heating element
$200 to $450
Sequencer
60 to 120 minutes
Arrival window
Price in writing before work starts · 90 day parts and labor warranty · After hours visits until 11 PM
Call 617) 440-9897
We repair furnaces from the condos near Marina Bay to the older houses off Hancock Street. Hours: Monday to Friday 7 AM to 6 PM, Saturday 8 AM to 2 PM. After hours calls: weeknights 6 PM to 11 PM, Saturday 2 PM to 11 PM, and Sunday 8 AM to 11 PM.
THE SHORT ANSWER
What does electric furnace repair include?
Electric furnace repair means finding the part that stopped the heat, testing it with a meter, replacing it, and running a full heating cycle before we leave. Most visits involve the heating elements, sequencer, limit switch, blower motor, control board, thermostat or breaker. We also check airflow and wiring connections, because they cause repeat failures.
THE HEAT CYCLE
How electric heat is made
This type of furnace is simple. It has fewer parts than a gas or oil unit, and each part has one job. When one fails, the symptom tells you where to look.
1
The thermostat calls for heat and sends a low voltage signal to the control board.
2
The sequencer, or a set of relays, closes in stages so the elements do not all start at once.
3
The heating elements, electric coils, heat up and glow.
4
The blower motor starts and pushes air across the elements and into your ducts.
5
If the air gets too hot, the limit switch cuts power to the elements. This protects the furnace.
10 to 20 kW
Home units often run between 10 and 20 kilowatts. Each element draws a large load on a 240 volt circuit. That is why loose wiring and failed breakers matter here.
NO FLAME, NO FUEL
What this furnace does not have
It burns no fuel. There is no gas line, no oil tank and no flue. That means the furnace itself makes no carbon monoxide.
It still runs on 240 volts, which is a real hazard. Never open the electrical panel or reach inside with the breaker on. A gas stove, a gas water heater or an attached garage can still be a carbon monoxide source, so keep your alarms.

TROUBLESHOOTING
Symptom guide: what you can check and when to call
| What you see | Likely cause | Safe to check yourself | Call us when |
|---|---|---|---|
| Blower runs, air is cold | Burned out elements, failed sequencer, tripped limit switch | Filter, breaker, thermostat set to heat | Cold air after 5 minutes |
| Nothing starts | Thermostat, breaker, transformer, blown fuse | Thermostat batteries, furnace switch, breaker (reset once) | Breaker trips again, or the display is dead |
| Runs nonstop, never reaches temperature | One or more elements dead, or a thermostat fault | Thermostat setting, filter | It never warms the house |
| Trips the breaker | Shorted element, failing motor, loose connection | Reset once | Right away if it trips again |
| Uneven heat from room to room | Weak airflow, failing sequencer, closed vents | Open vents, replace the filter | It continues after both checks |
| Short cycling | Limit switch tripping from restricted airflow | Replace a dirty filter | It continues with a new filter |
| Buzzing or humming | Failing blower motor or capacitor, chattering relay | Nothing | Right away |
| Burning smell | Dust on the elements, or a failing element or wire | Dust smell at first fall startup is normal for a few minutes | A smell that lasts. Turn the breaker off first |
Never open the furnace panel with the power on. These units carry high current, and the elements stay hot after the breaker is off.
REPEAT FAILURES
Why electric heat repairs fail twice
Elements do not burn out for no reason. Something made them run hot. If the technician swaps the element and leaves, the new one often follows the old one.
The usual culprits are restricted airflow, a failing sequencer that holds elements on too long, and a loose connection that heats up under load. We measure the amp draw on each element, check airflow and tighten the connections before we call a repair finished.

Why is the air from my furnace cold?
The blower is running but the heating elements are not. Causes include burned out elements, a failed sequencer, a tripped limit switch or a tripped breaker. Check the filter and breaker first. If the air stays cold, call a technician.
How can I tell an element is bad?
A bad element often shows a break, a blister or a burned spot on the coil. The reliable test is a meter. A good element draws amps when it is called for heat, and a dead one draws none. Turn the breaker off before you look.
Why does my furnace keep tripping the breaker?
A shorted heating element, a failing blower motor, a loose connection or a worn breaker can cause it. Reset it once. If it trips again, leave it off and call us. Repeated resets can overheat the wiring.
WHAT WE FIX
Electric furnace parts we repair or replace
Heating
- Heating elements and electric heating coils
- Sequencer and heat relays
- Electrical disconnect and wiring connections
- Fusible links and fuses
Safety controls
- Limit switch and high limit switch
- Overheat protection and safety interlock switch
Air movement
- Blower motor, blower wheel and blower fan
- Capacitor and fan relay
- Air filter and airflow testing
Controls and power
- Thermostat testing and replacement
- Control board and transformer
- Circuit breaker inspection
- Electrical connection inspection
See the heating element and sequencer repair page for how these parts are tested and priced.
If the heat is gone entirely, start with electric furnace not heating.
RUNNING COST
What electric heat costs to run in 2026
Basic service electricity rose on August 1, 2026. Eversource went from 15.6 to 17.3 cents per kWh. National Grid’s fixed option went from 15.4 to 17.2 cents, according to Boston.com.
About $1.70 an hour
A 10 kilowatt furnace running at full power uses 10 kWh an hour. At 17 cents, that is about $1.70 an hour. The furnace does not run flat out all day, but a cold week still adds up.
A heat pump moves heat instead of making it, so it uses less electricity for the same warmth. Mass Save has offered heat pump rebates and a 0% HEAT Loan for eligible homeowners. Check masssave.com for current terms before you replace anything.
A furnace in good repair costs less to run than a sick one. Weak elements make the furnace run longer to reach the same temperature. Read repair or replace your furnace before you decide.

LOCAL CONDITIONS
Where electric furnaces get stressed in Quincy
Gas is the main heating fuel in Quincy, but electric heat has a real share. In North Quincy (ZIP 02171), about 30.2 percent of homes heat with electricity, according to Census Bureau American Community Survey data. Gas is about 58 percent.
30.2%
of homes in North Quincy (ZIP 02171) heat with electricity.

| Area | What to know |
|---|---|
| North Quincy, along Hancock Street near the Red Line | Condos, apartments and older houses with electric heat. Furnaces and air handlers often sit in closets, where a clogged filter overheats the limit switch. |
| Marina Bay | Waterfront condos and townhouses. Check which system your unit has, and read your association rules before work starts. |
| Quincy Center, around Hancock Adams Common | Multi family buildings with tenants. Renters need fast repairs and a written record for the landlord. |
| Wollaston, off Newport Avenue and Beale Street | Most homes were built before 1940. Older electric panels and wiring can be undersized for a modern furnace load. |
| Houghs Neck, Adams Shore and Squantum | Coastal storms cause power flickers and outages. Surges damage control boards and relays. |
The furnace stops the moment the power does. If you run a portable generator after a storm, keep it outside and at least 20 feet from doors and windows. Never run it in a garage or basement.
SAFETY FIRST
Burning smell, sparks or a hot panel: do this first
1 Turn the furnace off at the breaker if you can reach it safely. If you see flames or heavy smoke, leave the house and call 911.
2 Do not touch the furnace or open the electrical panel cover.
3 If a CO alarm sounds, leave the house and call 911. The furnace is not the source, so we will help you find the cause after the fire department clears the house.
4 Call us. A furnace that sparked, smoked or tripped a breaker needs a full electrical test before it runs again.
Learn more on our inspection and CO check page.
TYPICAL CALLS
How we work through three common electric heat calls
These are typical calls, shown step by step, so you know what a good visit looks like.
CALL 01 — Blower runs, but the air is cold
The problem: The fan comes on and moves air, but nothing warm arrives. The house keeps cooling.
How we diagnose it: The technician turns the power off and checks the filter. He then restores power and measures amp draw on each element while the furnace calls for heat. He also checks the sequencer and the limit switch.
The fix: Replace the dead element or the failed sequencer, replace a weak limit switch, and tighten the connections.
What you get: Warm air at the vents, and a note on what made the part fail.
CALL 02 — Breaker trips as soon as the furnace starts
The problem: The furnace starts, then the breaker trips within seconds. Resetting it does the same thing.
How we diagnose it: The technician checks each element for a short to ground, tests the blower motor and capacitor, and inspects the breaker and wiring for burn marks.
The fix: Replace the shorted element or the failing motor, repair damaged wiring, and replace a worn breaker if the test shows one.
What you get: A furnace that runs a full cycle without tripping, and the failed part shown to you.
CALL 03 — Furnace runs all day and never warms the house
The problem: The furnace is on, the house stays 8 degrees under the thermostat setting, and the electric bill climbs.
How we diagnose it: The technician measures amp draw on every element. A furnace with a few dead elements still runs, but delivers only part of its heat.
The fix: Replace the dead elements, test the sequencer staging, and check the thermostat.
What you get: The furnace reaches temperature again and cycles off, instead of running nonstop.
PRICING
What electric furnace repair costs in Quincy
Most people call because they fear the bill more than the cold. So here is how we price.
The parts are not expensive. Most of the bill is the diagnosis and the labor, and the labor goes up if the furnace sits in a tight closet.
| Service | Price |
|---|---|
| Diagnostic visit | $89 |
| Heating element | $175 to $400 |
| Sequencer | $200 to $450 |
| Limit switch | $175 to $450 |
| Blower motor | $500 to $1,200 |
| Blower capacitor | $150 to $300 |
| Control board | $400 to $1,000 |
| After hours fee | $149 on top of the visit fee |
These are typical 2026 ranges for the Boston area. Repair prices include parts and labor, and they do not include the diagnostic visit or the after hours fee. Your written quote is the price you pay. If a quote lands far above these numbers, ask what is driving it.
Age × Quote > $5,000
Is it worth repairing an old electric furnace?
Multiply the furnace’s age by the repair quote. If the result is over $5,000, replacement usually wins. A 12 year old furnace with a $300 repair scores $3,600, so you repair it. An 18 year old furnace with a $400 repair scores $7,200, so you start comparing replacement. It is a rule of thumb, not a law.
Our full price page is furnace repair pricing in Quincy. Planning a new unit? Read the cost to install an electric furnace.
THE VISIT
How a service call works
1 You call (617) 440-9897. For no heat calls, we give you an arrival window of 60 to 120 minutes.
2 The technician starts with safety: power off, a look for burn marks, and a smell check.
3 He tests each element, the sequencer, limit switch, blower and thermostat, and shows you the part that failed and what caused it.
4 You get the price in writing. You say yes or no. There is no pressure to replace a furnace that can be repaired.
5 After the repair, we run a full heating cycle and measure amp draw before we leave.
Repairs carry a 90 day parts warranty and a 90 day labor warranty.

RENTALS
Landlords and tenants
DAY 68°F · NIGHT 64°F
In Massachusetts, the owner of a rental must provide heat. The state sanitary code (105 CMR 410) sets the minimum at 68°F during the day and 64°F at night. If the furnace is down in a rental, tell your landlord in writing and keep a copy.
Property managers can ask us for a written service record after each visit. See multi unit furnace service and no heat rules for rentals. After hours: emergency furnace repair.
SERVICE AREA
Where we repair electric heat
Every neighborhood, from Wollaston to Squantum, plus Braintree, Milton, Weymouth, Randolph and Holbrook. Check the service area page for the full list.
Wollaston · North Quincy · Quincy Center · Houghs Neck · Adams Shore · Squantum · Marina Bay · Braintree · Milton · Weymouth · Randolph · Holbrook
FAQ
Electric heat questions, answered
How much does electric furnace repair cost in Quincy?
The diagnostic visit runs $89. A heating element runs about $175 to $400, a sequencer $200 to $450 and a limit switch $175 to $450. Blower motors and control boards cost more. You get the price in writing before any repair starts.
Can I use a space heater while my furnace is down?
Yes, if it plugs straight into a wall outlet, sits at least 3 feet from anything that burns, and never runs while you sleep. Never use an extension cord, the oven or a grill. Turn the furnace breaker off first if you smell burning.
What size breaker does an electric furnace need?
It depends on the furnace’s kilowatt rating, which is on the nameplate. A licensed electrician sizes the breaker and wire. Never swap in a bigger breaker to stop it from tripping, because that can overheat the wiring.
How often should I change the furnace filter?
Check it monthly in winter and replace it every 1 to 3 months, depending on the filter and your home. A clogged filter makes the elements run hot and trips the limit switch.
Is a burning smell from my furnace normal?
A dusty burning smell for a few minutes the first time you run the furnace in the fall is normal. Dust burns off the elements. A smell that lasts, smoke or a hot plastic smell is not normal. Turn the breaker off and call us.
Do electric furnaces make carbon monoxide?
No. This furnace burns no fuel, so the furnace itself makes no carbon monoxide. A gas stove, a gas water heater or an attached garage can still be sources. If a CO alarm sounds, leave the house and call 911.
How long do electric furnaces last?
These furnaces often outlast gas ones, and 20 years or more is common with a clean filter. Heating elements wear out sooner than the furnace itself. Age matters most when you decide whether a big repair is worth it.
Is electric heat expensive in Massachusetts?
Basic service electricity rose to about 16 to 17 cents per kWh on August 1, 2026. A 10 kW furnace running at full power costs about $1.70 an hour. A heat pump uses less electricity for the same heat. Mass Save has offered heat pump rebates, so check current amounts.
Can I replace a heating element myself?
We do not recommend it. The furnace runs on 240 volts, and the wrong part or a loose connection can start a fire. Turn the breaker off and let a technician do it. We bring the part and test the full cycle.
What should I do if the furnace dies at night?
Check the thermostat, the furnace switch and the breaker. For a burning smell or smoke, turn the breaker off, leave and call 911. For a no heat call, ring (617) 440-9897. Our after hours window is weeknights 6 PM to 11 PM, Saturday 2 PM to 11 PM, and Sunday 8 AM to 11 PM. The after hours fee is $149.
Furnace down right now?
Call (617) 440-9897. Tell us what the blower does and what the thermostat shows. We will tell you what to check next.